Omron FH-1 series User Manual page 124

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

4 Setting the Controller
3
Click the icon portion of the processing unit to adjust.
To change the flow, use the [Edit flow] tool in the Toolbox Pane.
The settings dialog box for the selected unit is displayed.
4
Modify the processing units.
5
Click [OK].
The settings dialog box closes and the display returns to the Main Window (layout 1).
If you need to modify the judgement conditions for more than one processing unit, repeat steps
3 to 4.
At this stage, none of the changes have been applied.
6
In the Main Window for line 1, select [Non-stop data transfer] from the [Function] menu.
The changes to the settings for line 1 are saved as the settings for line 0 without affecting the
measurement.
7
Click the [Switch Screen] button to display the Main Window for line 0.
8
Click [Data Save] in the Function menu to save the settings.
Important
• When you execute [Non-stop data transfer], the results in the Trend Monitor and Expression
processing units are cleared.
• If you use an external command to switch scenes or scene groups, or change the settings of
processing units while the Controller is in RUN mode, the results of those changes will not be
applied when you change to line 1 (Adjustment Mode) in the Main Window.
• If you use the Non-stop Adjustment Mode after you change the scene group while the Con-
troller is in RUN mode, you may overwrite the scene group data unintentionally.
• The only communications commands that are accepted during a non-stop data transfer are
the measurement (parallel, non-procedure, or PLC Link) and continuous measurement (par-
allel only) commands.
• The larger the size of the scene group file, the longer the non-stop data transfer will take.
• The communications settings cannot be changed in Non-stop Adjustment Mode.
• Do not register a new Camera Image Input processing unit in the Non-stop Adjustment Mode
Window.
• If there is not enough RAMDisk space, the Nonstop data transfer may not perform.
Set the external storage device to save the Image logging, keep the RAMDisk space.
• Do not change the image mode for Non-stop Adjustment Mode.
• If you use image logging in Non-stop Adjustment Mode, the non-stop data transfer may
become unavailable. To avoid this, set the trigger frequency so that it is longer than the log-
ging time.
4 - 26
Vision System FH/FHV/FZ5 Series User's Manual (Z365)