8 Setting Windows
Check Box Setting Region
Parameter
Data Type
Target Unit No.
Unit label
Target data No.
[Data reference]
button
Data ident
ident 0
ident 1
Scene variable
System variable
Important
If you change the measurement flow after you create a custom dialog box, change the target
unit number to match the edited measurement flow.
8 - 82
Set value
[Factory default]
• [Unit data (No.)]
• Unit data (ident)
• System data
• Scene variable
• System variable
0 to Number of units in the
display target scene - 1 [0]
• [Unchecked]
• Checked
0 to 9999999 [0]
Description
Sets the unit specification method for targets for which to carry
out check box settings.
The settings details vary depending on specification methods.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
Use the unit number to specify the unit to be the target for the
check box setting.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box.
Select the processing unit to set.
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
If using the unit label to specify the unit to be the target for the
check box setting, select this and set the unit label.
Sets when [Unit data (No.)] is selected in the "Data Type".
Specify the data to be the target for the check box setting using
the data number.
Enter the data number for the unit that is specified by the target
unit number.
Sets when [Unit data (No.)] is selected in the "Data Type".
You can select the data number by directly entering it, or you
can enter it with the [Data reference] button.
Click the [Data reference] button to select the target data in the
[Data reference] dialog box.
Sets when [Unit data (ident)] is selected in the "Data Type".
Use the unit data (identifier name) to specify the unit to be the
target for the check box setting.
Sets when [System data] is selected in the "Data Type".
Specify the system data to be the target for the radio button
setting using the identifier information 0 and identifier informa-
tion 1.
(Refer to the Vision System FH/FZ5 Series Macro Customize
Functions Programming Manual (Cat No. Z367-E1) system
data list.)
Sets when [Scene variable] is selected in the "Data Type".
Specify the scene variable to be the target for the radio button
setting using the scene variable name.
Sets when [System variable] is selected in the "Data Type".
Specify the system variable to be the target for the check box
setting using the system variable name.