8 Setting Windows
Setting item
Cell Judge Min
Cell Judge Max
Control
Control ID
Status
Front/Back
Font Setting
Size
Style
Important
• Settings values in [Format Setting] specify variable names. You can not directly input numer-
ical values.
• Set subroutine name to specify in [Operation] in accordance with the following rules.
*+[Single-byte alphabetical character]+[Single-byte alphanumeric character and _ (under-
score)]
Example: *MEASUREDISP
8 - 46
Setting value
[Factory default]
Specifies the variable name for the character string array that
stores maximum and minimum values using up to 32 charac-
ters.
However, only variables in single dimensional array of charac-
ter string types that exist in the macro selected in [Macro Type]
can be specified. The number of array elements must be the
[Row Count] or higher. A separator character ";" needs to be
added between cell data in the same row.
If a value in the cell selected with [Cell Data] is a numerical
value, judge it with the specified maximum and minimum val-
ues and then display it in red if it is out of the range (NG). How-
ever, if neither the [Cell Judge Min] nor the [Cell Judge Max] is
[Blank]
specified, it is not compared.
If any of the following conditions are met, regardless of the set-
tings, the maximum (or minimum) value for all cells will be 0.
• Variable is not specified.
• Specified variable does not exist.
The maximum (or minimum) value of cells that meet any of the
following conditions, regardless of the settings, will be 0.
• Value is not specified.
• Value is out of range.
• Specified value is not numeric.
Sets when changing the status of data grid using a macro.
The ID used to identify the operation target if using the macro
0 to 999
RaiseOptionEvent relationship to carry out operations.
Set the status of Window Part.
Specifies the variable that stores the status of the display
screen for the data grid window from the variable assignment
window.
However, only the Scene variable or the System variable can
be specified.
[Blank]
Refer to "Assigning variables on page 5-61".
When the variable value is:
Positive: Move the window to the front.
Negative: Move the window to the back.
0:
Sets display font and display the set contents to the right of the
font setting area.
1 to 100 [14]
Sets the font size.
• Bold
• Italic
Sets the font style.
• Underline
• Strikeout
Description
Do not move the window.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)