Omron FH-1 series User Manual page 113

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Double Speed Multi-input
You can execute the measurement process with a multi-core CPU to inspect more measurement tar-
gets in less time than conventional processing would allow. This mode uses up to four CPU cores (or
eight threads) on a CPU that take turns in the execution of a single inspection flow every time the STEP
signal is input.
Refer to Multi-input Function on page 4-16.
Important
• The transaction time for a single workpiece is shorter if parallel processing is enabled to
allow parallel execution of the measurement flow.
Refer to 4-4-2 Parallel Processing on page 4-29.
• It is assumed that the [Double Speed multi-input] will be used together with the multi-input
function. Refer to Multi-input Function before you use the Double Speed Multi-input. When
the multi-input function cannot be used, the Double Speed Multi-input mode is not available.
Choose another mode than the Double Speed Multi-input mode.
Refer to Multi-input Function on page 4-16.
• Certain processing items, such as Serial Output, Parallel Output, and Parallel Judgement
Output, may slow the performance of the Double Speed Multi-input mode if they are pro-
grammed in the first half of the flow. If the performance drops significantly, consider the use
of parallel processing.
• Some processing items, such as Trend Monitor and Last NG Display, may not function cor-
rectly if Double Speed Multi-input is used. Do not use them. Calculation items that use the
numeric values from a previous STEP may not calculate correctly.
• You cannot use Simplified Non-stop Adjustment Mode during Double Speed Multi-input.
• External commands to obtain and set unit data will not operate correctly. Do not use them.
• If you use external commands, the BUSY signal will remain ON during command execution
longer than for other operation modes.
• Compared with other operation modes, it will take more time to perform processing which
includes screen transition, such as Scene switch, Scene group switch and Edit flow.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)