 Multi-input + Parallel processing OFF
STEP1
1
2
STEP
READY
BUSY
Input image
2.Camera
Image Input FH
Sensor Controller
Processing
After checking if READY is ON and BUSY is OFF, turn ON the STEP (STEP1).
1.
When STEP turns ON, READY turns OFF and BUSY turns ON.
Camera Image Input (2 Camera Image Input FH) is executed.
2.
After READY turns OFF and BUSY turns ON, turn OFF the STEP.
Since multi-input mode is selected for this example, READY turns ON after completing Camera Image
Input (2 Camera Image Input FH).
3.
After completing image input, measurement processing (3 Search) is executed.
After checking if READY is ON, turn ON the STEP (STEP2).
When STEP turns ON, READY turns OFF.
4.
Since multi-input mode is selected for this example, Input image (5 Camera Image Input) is performed in
the same way as 2 Camera Image Input FH.
5.
After READY turns OFF, turn OFF the STEP.
6.
After completing Input image (5 Camera Image Input FH), READY turns OFF.
Since Parallel processing is disabled, "6 Search" measurement processing is executed after "3 Search"
measurement processing is completed.
7.
The measurement is performed according to the flow setting.
After measurement processing is completed, BUSY turns OFF.
8.
Display processing (11 Result Display) is performed.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
STEP2
3
4 5
6
7
Input image
5.Camera
Image Input FH
Measurement
Measurement processing
processing
3.Search
6.Search
10 Advanced Usage
Measurement
Measurement
Measurement
processing
processing
processing
9.Conditional
8.Calculation
10.Search
Branching
8
10
Display
processing
11.Result
Display