10 Advanced Usage
 Non-Multi-input + Parallel processing ON
STEP1
1
2
STEP
READY
BUSY
Input image
2.Camera
Image Input FH
Sensor Controller
Processing
After checking if READY is ON and BUSY is OFF, turn ON the STEP (STEP1).
1.
When STEP turns ON, READY turns OFF and BUSY turns ON.
Camera Image Input (2 Camera Image Input FH) is executed.
2.
After READY turns OFF and BUSY turns ON, turn OFF the STEP.
After Camera Image Input (2 Camera Image Input FH), READY turns ON.
3.
Measurement processing (3 Search) is executed.
After checking if READY is ON, turn ON the STEP (STEP2).
4.
When STEP turns ON, READY turns OFF.
Since Non-Multi-input mode is selected, processing starts with camera settings for 5 Camera Image Input.
5.
After READY turns OFF, turn OFF the STEP.
After completing Camera Image Input (5 Camera Image Input FH), measurement processing (6 Search) is
6.
executed without turning ON the READY.
After measurement processing (6. Search) is completed, READY turns ON.
7.
After "1 Multi-trigger Imaging Task" and "4 Multi-trigger Imaging Task" are completed, measurement pro-
cessing (8 Calculation) which is set after the Multi-trigger Imaging End is performed.
After measurement processing of Multi-trigger Imaging End is completed, READY turns ON and BUSY
turns OFF.
8.
Display processing (11 Result Display) is performed.
10 - 26
STEP2
3
4 5
6
Camera
Input image
settings
5.Camera
Image Input FH
Measurement
processing
3.Search
Measurement processing
6.Search
7
Measurement
Measurement
Measurement
processing
processing
processing
9.Conditional
8.Calculation
10.Search
Branching
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
8
Display
processing
11.Result