Omron FH-1 series User Manual page 105

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Important
• Do not set [EtherNet/IP] and [PLC Link] at the same time. They cannot be used at the same
time.
Example:
Set [Serial (Ethernet)] to [PLC Link] and [Fieldbus] to [EtherNet/IP] at the same time.
Set [Serial (RS-232C/422)] to [PLC Link] and [Fieldbus] to [EtherNet/IP] at the same time.
Set both [Serial (Ethernet)] and [Serial (RS-232C/422)] to [PLC Link], and set [Fieldbus] to [Ether-
Net/IP] at the same time.
• Do not set both [Serial (Ethernet)] and [Serial (RS-232C/422)] to [PLC Link]. They cannot be
used at the same time.
Additional Information
• Normal (Fxxx Series Method)
With the [Normal (Fxxx series method)] communications method, the OK response timing in
relation to MEASURE commands is different from that of the [Normal] communications
method.
Normal (Fxxx series method) communications method
MEASURE
Measurement result
OK
• OK Responses
With [Normal communications method], an OK response is returned when the Controller
receives a command.
With [Normal (Fxxx series method)], an OK response is returned when command execution
is completed.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
4 Setting the Controller
Normal communications method
MEASURE
OK
Measurement result
4
4 - 7