Omron FH-1 series User Manual page 348

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

8 Setting Windows
Setting item
Display mode
Macro Func.
Pre-Process
Post-Process
Status
Enable
Selected
Front/Back
Control
Control ID
8 - 54
Setting value
[Factory default]
• Modeless
Sets the display mode.
• [BUSY ON]
Modeless:
BUSY ON: Select this when setting BUSY to ON while a
Sets this before and after starting the Setup window when call-
ing a macro subroutine.
[Blank]
Specifies the subroutine name (including *) to execute before
displaying the Setup window using up to 32 characters.
[Blank]
Specifies the subroutine name (including *) to execute after
closing the Setup window using up to 32 characters.
Sets the status for the window part.
[Blank]
Specifies the variable to store the text display window status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
0:
Other than 0:Set the Custom dialog to enabled state.
[Blank]
Specifies the variable to store the text display window status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
0:
Other than 0:Set the Custom dialog to selection state.
[Blank]
Specifies the variable to store the text display window status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
When the variable value is:
Positive:
Negative:
0:
Sets when changing the status for the processing item setting
window display button using a macro.
0 to 999 [0]
The ID used to identify the operation target when using the
macro RaiseOptionEvent relationship to carry out operations.
Description
Select this when using a display in which other
operations can be executed or other window parts
can be started (modeless display) while a speci-
fied Custom dialog is started.
specified Custom dialog is started.
Set the Custom dialog to disabled state.
Set the Custom dialog to normal state.
Move window to the front.
Move window to the back.
Do not move the window.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)