Omron FH-1 series User Manual page 139

Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

1
In the Main Window, select [System settings] − [Camera] − [Inter-camera setting] from the [Tool]
menu. The Inter-camera Settings View is displayed.
2
Click a camera number to set the delay between STEP-cameras and then specify the delay
count value.
Item
Delay count
between STEP-
cameras
Transmission
speed
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Set value
[Factory default]
• FH series Sensor Controller:
-4 to 511
[0]
(1 count is 30 μs)
• FZ5 series Sensor Control-
ler:
0 to 511
[0]
(1 count is 30 μs)
[Standard] or High speed
Description
Sets the delay time from when the STEP signal is received to
when exposure begins for the selected Camera.
The delay time differs in FH series / FZ5 series.
• Delay time of FZ5 series Sensor Controller:
The time displayed for STEP-camera delay time is delay
count between STEP-camera × 30 μs + 122 μs
• Delay time of FH series Sensor Controller:
When using cameras other than FH-S05R, the time dis-
played for STEP-camera delay time is (STEP-camera
delay counts × 30 μs + 122 μs) + 120 μs.
When using the FH-S05R camera, the time displayed for
STEP-camera delay time is (STEP-camera delay counts ×
30 μs + 122 μs) + 470 μs.
When using the FH-S21R camera, the time displayed for
STEP-camera delay time is (STEP-camera delay counts ×
30 μs + 122 μs) + 1123 μs.
When you connect a camera that supports High speed mode
using a camera cable shorter than 5m, image input time can
be shortened by selecting [High speed] for frame rate.
For details about frame rate values, refer to the Instruction
manual for the Camera.
The following cameras support [High speed]:
• FH-SC02/FH-SM02
• FH-SC04/FH-SM04
• FH-SC12/FH-SM12
• FH-SCX/FH-SMX
• FH-SCX05/FH-SMX05
• FH-SCX12/FH-SMX12
• FH-SC21R/FH-SM21R
4 Setting the Controller
4 - 41
4

Advertisement

Table of Contents
loading