10 Advanced Usage
Timing Chart
 Multi-input + Parallel processing ON
STEP1
1
2
STEP
READY
BUSY
Input image
2.Camera
Image Input FH
Sensor Controller
Processing
After checking if READY is ON and BUSY is OFF, turn ON the STEP (STEP1).
When STEP turns ON, READY turns OFF and BUSY turns ON.
1.
Camera image (2 Camera image input FH) is input.
2.
After READY turns OFF and BUSY turns ON, turn OFF the STEP.
Since multi-input mode is selected for this example, READY turns ON after completing Camera Image
Input (2 Camera Image Input FH).
3.
After completing Input image (2 Camera Image Input FH), measurement processing (3 Search) is exe-
cuted.
After checking if READY is ON, turn ON the STEP (STEP2).
When STEP turns ON, READY turns OFF.
4.
Since multi-input mode is selected for this example, Input image (5 Camera Image Input) is performed in
the same way as 2 Camera Image Input FH.
5.
After READY turns OFF, turn OFF the STEP.
After completing Input image (5 Camera Image Input FH), READY turns OFF.
In this example. parallel processing is activated; Multi-trigger Imaging Task blocks are performed in paral-
6.
lel.
After completing Input image (5 Camera Image Input FH), measurement processing (6 Search) is exe-
cuted.
After "1 Multi-trigger Imaging Task" and "4 Multi-trigger Imaging Task" are completed, measurement pro-
7.
cessing (8 Calculation) which is set after the Multi-trigger Imaging End will be performed.
After measurement processing is completed, BUSY turns OFF.
8.
Display processing (11 Result Display) is performed.
10 - 24
STEP2
3
4
5
6
Input image
5.Camera
Image Input FH
Measurement
processing
3.Search
Measurement processing
6.Search
7
Measurement
Measurement
Measurement
processing
processing
processing
9.Conditional
10.Search
8.Calculation
Branching
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
8
Display
processing
11.Result
Display