Advertisement

4
Set SHTOUT for each line in the [Line setting] area.
Parameter
SHTOUT signal delay [μs]
SHTOUT signal pulse width [μs]
SHTOUT signal pulse polarity
Important
Do not perform next camera image input processing before SHTOUT signal output is com-
pleted. SHTOUT signal may not be output.
Perform camera image input processing after confirming SHTOUT signal output completion, or
set the SHTOUT signal delay and SHTOUT signal pulse width so that the SHTOUT signal out-
put is completed before camera image input processing.
5
Click the [Close] Button.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)
Set value [Factory default]
[0] to 1,000
40 to 10,000 [5,000]
• [Positive]
• Negative
4 Setting the Controller
Description
Sets the delay time from when exposure is
completed to when the SHTOUT signal turns
ON in increments of 10 μs.
Sets the time to output the SHTOUT signal in
increments of 10 μs.
Set the polarity of the SHTOUT signal.
Positive: The SHTOUT signal changes from
OFF to ON when the exposure ends.
Negative: The SHTOUT signal changes from
ON to OFF when the exposure ends.
4
4 - 45