6 Performing Measurement and Adjustment
b) Control area
(1) Target area
Sets images to be measured: Logging image or Image file.
When selecting the "Image file", the text box under the "Image file" becomes active.
Clicking [...] in the right side of the text box displays "Select folder" dialog below. Specify a
folder containing images to re-measure.
(2) Execute batch measurement button
When clicking the button, all of the specified target images are re-measured continuously.
(3) Save data
Outputs re-measured results to a selected folder as a CSV file.
When clicking the button, FileExplorer will be displayed. Select the folder and set the file
name.
(4) Remeasure Image
Displays images for items selected in the results display area.
6 - 32
[<]/[>]: Switch images.
[→OK folder]: Update OK classification
[←NG folder]: Update NG classification
[Setup (Std. image)]: Adjust settings with the reference image.
[Setup (Select image)]: Adjust settings with a selected image.
Vision System FH/FHV/FZ5 Series User's Manual (Z365)