Connecting Outputs - Interlogix ZeroWire ZW-6400 Reference Manual

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

9.24 Connecting Outputs

ZeroWire has two general purpose outputs located on the rear of the unit. See illustration in
section 9.23, Connecting Inputs. These can be connected to up to 2 devices. Use the supplied
header cable.
Outputs are controlled by Actions in the ZeroWire.
When an output is configured with an action, the output will monitor the status of the action:
 When the action logic is true, the output will be on
 When the action is false, the output will be off
If no action is assigned to an output the default behaviour is:
 Output 1 = Siren
 Output 2 = Strobe
To program outputs from ZeroWire Web Server:
1. Press Advanced – Actions.
2. Create an Action – refer to
3. Press Advanced – Devices – System Devices – Control.
4. Press Control Output 1 or Control Output 2.
5. Press Action Assignment.
6. Press the drop down action menu and select the action you want to control the output.
The output will now be controlled by the state of the selected action.
C
...
...
185
P/N 466-5227 • REVA • ISS 26AUG15
Actions Programming
ZeroWire Reference Guide
(Advanced) for more help.
©2015 United Technologies Corporation
I
..
...
.. .
..

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents