Interlogix ZeroWire ZW-6400 Reference Manual page 138

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

When a system event occurs, it is routed to the System Event Channel Group
(Communicator\System Event Reporting\System Channels). The Channel Group will forward
the event to each of the Channels it contains. If the event is on the Channel's Event List, the
Channel will attempt to send the event to the Channel's destination.
Example System Event
AC Fail
System Event
Reporting
Channel Group 1
Channel Group 1
Channel 1
Channel 2
Channel 3
Event List 1
Critical
Bypass & Restore
AC Fail
If a sensor or area event is generated, then the event is sent to the Channel Group
specified (Area – Channel Group) in the lowest area the sensor belongs to. The Channel
Group forwards the event to each of the Channels it contains. Each Channel checks its Event
List to determine if the event should be sent.
Example Sensor or Area Event
Sensor 3 in Alarm
Area Group = 1
Area Group 1
Area 1
Area 2
Event sent to lowest area
Area 1
Channel Group
Area sends event
to Channel Group
Channel Group 1
Channel 1
Channel 2
Channel 3
C
...
...
138
P/N 466-5227 • REVA • ISS 26AUG15
System sends
event
to
Channel Group
Channel Group
sends event
to every
Channel it contains
Event List 2
Informational
Alarms
Open & Closes
Auto test
Sensor sends alarm to area group
1
Channel Group sends Event
to every Channel It contains
Channel 1
Control Room 1
Event List = 1
Channel Attempts = 3
Next Channel = 4
Channel 2
Control Room 2
Event List = 1
Next Channel = 5
Channel 3
Email
Event List = 2
Next Channel = 0
Channels 1 and 2 will attempt to send the event as AC Fail is on the
corresponding Event List. Back up channels 4 and 5 will also attempt
to send the event if they are used.
Channel 3 will NOT send the event as Event List 2 does not include
AC Fail events.
Channel 1
Control Room 1
Event List = 1
Channel Attempts = 3
Next Channel = 4
Channel checks to see if the
event is on its Event List; if
yes it will attempt to send, if
not it will stop.
Channel 2
Control Room 2
Event List = 1
Next Channel = 5
Channel 3 Email
Event List = 2
Next Channel = 0
ZeroWire Reference Guide
Channel 4
Control Room 1
Event List = 1
Channel Attempts = 3
Next Channel = 0
Channel 5
Control Room 2
Event List = 1
Next Channel = 0
Channel 4
Control Room 1
Event List = 1
Channel Attempts = 3
Next Channel = 0
If it does not succeed after
Channel Attempts, it will try
sending on the next Channel.
Channel 5
Control Room 2
Event List = 1
Next Channel = 0
©2015 United Technologies Corporation