The following conditions must be true before a timed area disarm function will occur.
a.
The area type must be set to Timed Disarm.
b.
The area type schedule must be active.
The users active profile's permission must have;
c.
This area set in the permission's timed disarm area group.
i.
ii.
The permission must be in schedule.
The permission's Area Type Override must NOT be set.
iii.
At the end of the user's disarm time, the Area Type Delay will activate for the set period. At the end of the
Area Type Delay period the area will arm and start the Exit Delay and if configured, report a closing using
via the last user number to have time disarmed the area.
At anytime during the timed disarm period, authorised users with Area Type Override set in their active
profile can cancel the disarm time period by arming or disarming the area.
The user's permission determines how long the area will be disarmed for.
Man Down
Man down is used when an authorised user(s) is working in a hazardous area (or the like), and there is a
requirement that the user(s) regularly "check-in" to notify others that the user(s) is safe. If the authorised
user(s) fails to perform this action the system can set an audible warning and send a report.
The following conditions must be true before man down function will occur.
a.
The area type must be selected to man down.
b.
The area type schedule must be active (after the start time and before the end time).
The uses active profile's permission must have;
c.
This area set in the permission's man down group.
i.
ii.
The permission must be in schedule.
The permission's Area Type Override must NOT be set.
iii.
The man down timer is set in the user's permission.
At the end of the user's man down time, the Area Type Delay will activate for the set period. At the end of
the Area Type Delay period the area will arm and if configured, report a man down alarm. At anytime
during the man down period, authorised users with the Area Type Override set in their active profile will
cancel the man down time period by disarming or disarming the area.
Guard Tour
Guard tour is used when an authorised user(s) (such as a guard) is required to regularly "check-in" to
notify others that they have physically attended to a location(s) on the site. If the authorised user(s) fails to
perform this action the system can set an audible warning and report a "Guard Tour Fail" event.
The following conditions must be true before guard tour function will occur.
a.
The area type must be selected to guard tour.
b.
The area type schedule must be active (after the start time and before the end time).
The uses active profile's permission must have;
c.
This area set in the permission's guard tour group.
i.
ii.
The permission must be in schedule.
The permission's Area Type Override must NOT be set.
iii.
The guard tour time is set in the user's permission.
At the end of the user's guard tour time, the Area Type Delay will activate for the set period and keypad
sounder will be active. At the end of the Area Type Delay period the area will arm and if configured, report
a Guard Tour Fail alarm. At anytime during the guard tour period, authorised users with the Area Type
Override set in their active profile will cancel the guard tour time period by disarming or disarming the
area.