3 Sensor Options
Also see the
Sensor Options
Bypassed Stay Mode – if enabled, this sensor is automatically bypassed when the area is armed in
stay mode. For example, it is an interior sensor.
Force Arm Enabled – if enabled, this sensor type may be unsealed while arming if forced arming is
enabled in the area options. Normally all sensors in an area must be sealed before a user can
attempt to arm that area.
Bypass – if enabled, this sensor may be bypassed.
Cross Zone– This sensor type will require two triggers or another sensor would have to have been
trigged before it will activate an alarm.
EOL – Enable End Of Line resistor tamper monitoring
Automatic Sensor Test – if enabled, this test is controlled by action results automatic test on and off.
Sensor Inactivity Test – if enabled, this sensor will check for Sensor Inactivity. The Sensor Inactivity
setting must be enabled in General Options. The time is programmed in Sensor Inactivity Time. See
Programming the
Follow Any Armed Area – If enabled, and a sensor is in more than 1 area it will create an alarm if
triggered when any area is armed. If this feature is off then all the areas must be armed before the
sensor will become active.
If sensor is type 10 sensor (Interlogix Door/Window sensor) then these two options apply:
Disable Internal Reed Switch – check this box when using external contacts.
Normally Open External Contact – check this box when external contact is normally open.
These two options appear in the Web Server – Settings – Sensors page, and under
Advanced\Devices\Interlogix Transmitters\Transmitter Number\Options.