Interlogix ZeroWire ZW-6400 Reference Manual page 133

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

3 Sensor Options
Also see the
Sensor Options
 Bypassed Stay Mode – if enabled, this sensor is automatically bypassed when the area is armed in
stay mode. For example, it is an interior sensor.
 Force Arm Enabled – if enabled, this sensor type may be unsealed while arming if forced arming is
enabled in the area options. Normally all sensors in an area must be sealed before a user can
attempt to arm that area.
 Bypass – if enabled, this sensor may be bypassed.
 Cross Zone– This sensor type will require two triggers or another sensor would have to have been
trigged before it will activate an alarm.
 EOL – Enable End Of Line resistor tamper monitoring
 Automatic Sensor Test – if enabled, this test is controlled by action results automatic test on and off.
 Sensor Inactivity Test – if enabled, this sensor will check for Sensor Inactivity. The Sensor Inactivity
setting must be enabled in General Options. The time is programmed in Sensor Inactivity Time. See
Programming the
 Follow Any Armed Area – If enabled, and a sensor is in more than 1 area it will create an alarm if
triggered when any area is armed. If this feature is off then all the areas must be armed before the
sensor will become active.
If sensor is type 10 sensor (Interlogix Door/Window sensor) then these two options apply:
 Disable Internal Reed Switch – check this box when using external contacts.
 Normally Open External Contact – check this box when external contact is normally open.
These two options appear in the Web Server – Settings – Sensors page, and under
Advanced\Devices\Interlogix Transmitters\Transmitter Number\Options.
C
...
...
133
P/N 466-5227 • REVA • ISS 26AUG15
table for reference.
System, section 4.4.
ZeroWire Reference Guide
©2015 United Technologies Corporation
I
..
...
.. .
..

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents