Connecting Hardwire Devices; Ac Terminals; Hwin1, Hwin2, And Dcout Terminals; Wiring Interior Sirens - Interlogix Simon 3 Installation Instructions Manual

Hide thumbs Also See for Simon 3:
Table of Contents

Advertisement

Installing the System
Figure 3. Panel Mounting Hole Locations
4.
For wall mounting, insert anchors into holes where
studs are not present.
5.
Install all screws and tighten gently.

Connecting Hardwire Devices

The panel has 5 screw terminals located on the upper-right cor-
ner of the circuit board (see Figure 3) for connecting AC
power, sirens and/or hardwire detectors.

AC Terminals

These terminals are used for connecting a 9 VAC, 700 mA AC
power transformer. For systems with no X-10 modules, use
transformer part no. 22-109-ITI. For systems with X-10 mod-
ules, use transformer part no. 22-TBD-ITI

HWIN1, HWIN2, and DCOUT Terminals

These terminals are dual purpose and can be used for either
siren or hardwire detector connections.
Note
These terminals cannot provide both functions simulta-
neously.
From the factory, these terminals are set up for siren operation
with HWIN1 handling interior sirens (status and alarm
sounds), HWIN2 handling exterior sirens (alarm sounds only),
and DCOUT providing the positive (+) voltage.
Note
The combined total current available from HWIN1 and
HWIN2 is 250 mA.
6
Beta Test 8/10/01
Mounting
Holes
To set up HWIN1 and/or HWIN2 for hardwire detectors, make
the required connections as described under "Wiring Hardwire
Detectors," then proceed to the "Programming" section to add
(learn) them into panel memory.

Wiring Interior Sirens

Panel terminal HWIN1 can be used for connecting interior
sirens and activates for status and alarm sounds.
Interior sirens must be wired with a resistor in the circuit. For
circuit supervision which allows the panel to detect if the siren
wire is cut (open), Option 53: Hardwire Siren Supervision
must be turned on (see the "Programming" section).

LD105 Hardwire Interior Siren

Connect the LD105 Hardwire Interior Siren (13-374) to the
panel using a 4.7k resistor (included with siren) as shown in
Figure 4. The resistor must be connected across the siren wires
as close to the siren as possible.
Note
Do not install the resistor at the panel terminals. This
does not provide supervision of the wire.
A C
A C
H W I N 2
4.7k Resistor
(Locate at siren)
Figure 4. Hardwire Interior Siren with Supervision
If a siren is not connected to the HWIN1 and DCOUT termi-
nals, Option 53 must be turned off.
D C O U T
H W I N 1
RED
BLACK