10 Event Start Range
Select the starting number of the event that you want
the Action to monitor. This is related to a number
range. For example this might be the first area or
sensor number.
12 Event Combination Logic
The logic condition to apply to Event 1
OR
Inverted OR
AND
Inverted AND
RESET
The Combination Logic selected for each event places the logic prior to the event in an equation.
Selecting the AND logic closes a parenthesis for the previous event. The DLX900 software displays an
Event Equation field to make it easier to construct Actions.
For example,
Event 1 Inverted OR,
Event 2 OR,
Event 3 AND,
Event 4 OR
produces a logic equation of:
(NOT Event 1 OR Event 2) AND (Event 3 OR Event 4)
C
...
...
113
P/N 466-5227 • REVA • ISS 26AUG15
e.g. Area 1 Armed Away OR Area 2 Armed Away
e.g. Not Sensor 1 Bypass OR Sensor 2 Bypass
e.g. Area 1 Armed Away AND Area 2 Armed Away
e.g. Not Sensor 1 Bypass AND Sensor 2 Bypass
Reset any latched event
ZeroWire Reference Guide
11 Event End Range
Select the ending number of the event that you
want the Action to monitor. This is related to a
number range. For example this might be the last
area or sensor number.
If you just want to monitor one item, then leave it
at the default of zero, or enter the same number
as Event Start Range.
©2015 United Technologies Corporation