4 Sensor Reporting
Alarms Reporting – if enabled, this sensor will
report alarms.
Alarm Restores Reporting – if enabled, this
sensor will report alarms.
Bypass-Unbypass Reporting – if enabled, this
sensor will report bypasses and unbypass
restorals.
Sensor Lost-Low Battery Reporting – if enabled,
this sensor will report loss of wireless supervision
and low battery faults.
Sensor Trouble and Restore – if enabled, this
sensor will report sensor trouble and restorals.
Fire type sensors will always report regardless of
this option.
6 Sensor Report Event
From the drop down menu, select the CID and SIA event code to report when this sensor is tripped.
C
...
...
134
P/N 466-5227 • REVA • ISS 26AUG15
5 Sensor Contact Options
(Applies to the hardwire inputs, not wireless
sensors.)
Normally Open no EOL – if enabled, the sensor
circuit is normally open. Default is off.
Fast Loop – if enabled, the ZeroWire will be
more sensitive and respond quicker to a change
in state to the sensor. For example, we could
enable this on a door contact to trigger the
turning on of lights quicker when someone
opens the door by using an Action. Depending
on the application this may increase the chance
of a false alarm if the sensor is used for intrusion
detection.