8 User Number
The sensor user number feature is used whenever the sensor type is set to "keyswitch". Instructions for
users configuration are in Section 6 –
allocated to any sensor's user number. ZeroWire sensor profile user number is a powerful feature that is
used to apply the selected user's attributes to a keyswitch operation. When the keyswitch sensor is
activated, ZeroWire will check the user permissions and permission schedules to determine which areas
are accessible. Additionally, area open and close reports will also report the user number selected in this
option. If the user number is programmed to 0, the ZeroWire will use a default User number of 999 and
will operate on all areas in the sensors area group
9 Second Sensor Profile (Refer to First Sensor Profile)
Example Diagram
Sensor 12 – Carpark Motion Sensor
First Sensor Profile
Sensor Programming
C
...
...
85
P/N 466-5227 • REVA • ISS 26AUG15
Sensor Type – Event Only
Sensor Options – Bypass Forced Arm
Schedule 1 – Office Hours
Mon-Fri, 8am-6pm, Holidays
Event Only
8am
Users and
Permissions. One of 40 configurable users can be
.
Second Sensor Profile
Sensor Type – Always On
Sensor Options – Bypass Forced Arm
Schedule 2 –
Always On All Days, 24/7
1
Always On
6pm
ZeroWire Reference Guide
8am