Interlogix ZeroWire ZW-6400 Reference Manual page 87

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

3 Area Entry-Exit times
ZeroWire uses the area entry and exit timers to delay the activation of an alarm event when entry/exit
sensor types are activated.
When an area is turned on, it will start an Exit 1 timer. While an Exit 1 timer is running – Entry 1, Entry 2,
and Handover sensor types will not create an alarm.
When the Exit 1 timer expires it will start the Exit 2 timer. While an Exit 2 timer is running – Entry 2
sensors will not create an alarm.
Once all exit delays are expired, an activation on an Entry 2 sensor type will start an Entry delay with the
Entry 2 time, and an activation of an Entry 1 sensor type will start an Entry delay with the Entry 1 time.
If an entry delay is running and a sensor is activated with an entry time that is less than the time
remaining, the timer will be reduced to the time of that new sensor.
Activation of a Handover sensor while an entry timer is not running will create an instant alarm.
If a sensor is in more than 1 area, the sensor will use the have the longest entry and exit delay time of the
programmed area. If a area greater than 1 has the time set to 0, that area will use the time programmed in
Area 1.
If area settings are set to 0, then the area will automatically inherit Area 1 settings.
1. Entry Time 1
Entry time 1 is used to time the entry delay when an entry delay is started by an entry 1 sensor type.
2. Exit Time 1
Whenever a area is turned on, it will start an Exit 1 timer. Entry 1, Entry 2, and Handover sensor types will
not create an alarm if triggered while an Exit 1 timer is running.
3. Entry Time 2
Entry time 2 is used to time the entry delay when an entry delay is started by an entry 2 sensor type.
4. Exit Time 2
When the Exit 1 timer expires it will start the Exit 2 timer. Entry 2 sensors will not create an alarm if
triggered while an Exit 2 timer or an Exit 1 timer is running.
5. Stay Entry Time
The stay entry time is the entry warning time that applies to all sensors armed in the stay mode. Entry 2
sensors will follow Entry 2 time and will ignore this setting. This stay entry time does not apply to fire
sensor types.