Interlogix ZeroWire ZW-6400 Reference Manual page 94

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

Early Open/Late Close
If the area type is Early Open & Late Close, the Area Type Delay sets the period after the start (opening)
and the end (closing) of the area type schedule that the area must be either disarmed or armed.
For example, if the area type schedule is set between 8:00 AM (opening time) and 5:00 PM (closing time)
and the Area Type Delay is set to 15 minutes; then the area must be disarmed between 8:00 AM and 8:15
AM otherwise if it is disarmed before 8:00 AM it is an early open, if it is disarmed after 8:15 AM it is late to
open. Likewise the area must be armed between 5:00 PM and 5:15 PM otherwise if it is armed before
5:00 PM it is an early close, if it is armed after 5:15 PM it is late to close.
7 Area Type Schedule
One of 96 configurable schedules can be allocated to the area type schedule. The area type schedule
determines the schedule that the selected area type is active. Area types are not active when the
schedule is not active. If a area type schedule is disabled (always active) that area will always have the
type characteristics programmed in Area Type.
Area Type Delay
If the area type is Standard and Arm / Disarm is configured, this timer delays arming by the minutes
entered.
If the area type is Timed Disarm, Man Down, or Guard Tour, this setting is a warning time given to a user
once the user's Disarm Time, Man Down Time, or Guard Tour Time has expired. During this warning time
a user can cancel the automatic re-arming and event report by entering their code, this will also restart the
appropriate user timer. At the end of the warning time the ZeroWire will re-arm the area and send the
appropriate event (closing, man down, guard tour fail).
If the area type is Early Open & Late Close, this timer sets the period after the start (opening) and after the
end (closing) of the area type schedule that the area can be disarmed or armed. Otherwise an early to
open or late to close report will be sent if enabled in user permissions. Fail to open and fail to close report
will be sent if Arm-Disarm Reports is enabled in area options.
C
I
...
...
94
..
...
ZeroWire Reference Guide
P/N 466-5227 • REVA • ISS 26AUG15
©2015 United Technologies Corporation
.. .
..