9.22 Wall Tamper Option

1. CAUTION: Wall tamper is an optional security feature that is disabled by default. When
enabled, the siren will make a very loud alarm sound when power is connected.
Press 9-7-1-3 Enter to turn the siren off. If this does not work, reset the Installer account:
a. Disconnect power.
b. Use a small screwdriver to hold down the reset button.
c. Turn on power and keep holding down reset button for 3 seconds, then release the
reset button. This will reset user number 256 to PIN 9-7-1-3 and username to
installer.
2. Lights should be lit on the ZeroWire when the power is turned on. If not check that the
power lead is connected securely to the rear of the ZeroWire.
Avoid using multiple power adapters and power boards. ZeroWire is designed to be
connected at all times to a power source; it is NOT designed to run from the battery pack.

9.23 Connecting Inputs

ZeroWire has two general purpose inputs located on the rear of the unit. These can be
connected to up to 4 devices when Sensor Doubling is enabled. Use the supplied header
cable.
C
...
...
183
P/N 466-5227 • REVA • ISS 26AUG15
ZeroWire Reference Guide
1. Ground
2. Input 1
3. Input 2
4. Output 1
5. Output 2
6. 8.5V+
©2015 United Technologies Corporation