Interlogix ZeroWire ZW-6400 Reference Manual page 89

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

6. Siren Chirp Stay
If enabled, the ZeroWire will activate the built-in siren briefly each time this area is set in stay mode with a
key-switch sensor or wireless keyfob.
7. Force Arm With Bypass
If enabled, the area can be armed even if sensors are not ready. Any sensors that are not ready will
automatically be bypassed, log the bypass, and optionally report the bypass.
The automatic bypass will be applied when the sensor is capable of causing an alarm condition due to a
state change such as an area arming, schedule or action. This avoids false alarms.
If an auto-bypassed sensor becomes ready after it is armed, that sensor will automatically remove the
bypass, log the bypass restore, and optionally report the bypass restore.
Individual sensors can be made "force armable with auto-bypass" by leaving this area option off, then
enabling Forced Arm Enable in Sensor options, and enabling Sensor Inhibit (Bypass) in the Sensor Type
Profile.
8. Force Arm Without Bypass
If enabled, the area can be armed even if sensors are not ready. Any sensors that are not ready will NOT
be automatically be bypassed and may cause an alarm condition because they could still be in a not ready
state once the area becomes armed.
This option is overridden if the Force Arm With Bypass is enabled.
Individual sensors can be made "force armable without auto-bypass" by leaving this area option off, then
enabling Forced Arm Enable in Sensor options, and disabling Sensor Inhibit (Bypass) in the Sensor Type
Profile.
9. Silent Exit
If enabled, ZeroWire not sound the exit warning beeper.
10. Manual Fire
If enabled, the manual fire button will be enabled on keypads. Press and hold for 2 seconds to send a fire
event. Default is off.
11. Manual Auxiliary
If enabled, the manual auxiliary button will be enabled on keypads. Press and hold for 2 seconds to send
an auxiliary event. Default is off.
12. Manual Panic
If enabled, the manual panic button will be enabled on keypads. Press and hold for 2 seconds to send a
panic event. Default is off.
13. Use Area 1 Options
If enabled, the area will use Area 1 options. Default is on.
14. Bypass Requires PIN
If enabled, a valid PIN code with access to this area is required to bypass sensors in this area.
15. Manual Panic is Silent
If enabled (in Settings), manual panic alarms will not trigger an audible alarm.
C
I
...
...
89
..
...
ZeroWire Reference Guide
P/N 466-5227 • REVA • ISS 26AUG15
©2015 United Technologies Corporation
.. .
..

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents