1 Siren Options
1. Siren Once Per Sensor
If enabled, the ZeroWire will only set the siren once per sensor in a given arm cycle and will not set the
siren again even if that siren time expires and that sensor reactivates. Every sensor will have one siren
activation attempt before that sensor cannot reactivate the siren. If this option is not enabled, at the
expiry of the siren time any sensor can reactivate the siren an unlimited number of times.
2. Siren At System Away/Disarm
If enabled, the ZeroWire will activate the built-in siren briefly each time the last area in the system is set
in away mode or when the first area is disarmed. To enable this function by area, leave this option
disabled in this section, and enable the "Siren at System Away/Disarm" in section 5.3
Areas
Programming
(Advanced) for the area(s) you require.
3. Siren At End Of Exit
If enabled, the ZeroWire will activate the built-in siren briefly each time the system is set in away mode
and the exit delay expires.
4. Siren At Arm Report
If enabled, the ZeroWire will activate the built-in siren briefly every time the system is set in away
mode, the exit delay expires and a successful system arm report is completed.