Interlogix ZeroWire ZW-6400 Reference Manual page 47

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

Option
Date
Time (hh:mm:ss)
Hours Offset
Minutes Offset
Start Month
Start Week
End Month
Start Month
Siren Time (0-99)
Minutes
Battery Test Timer (0-
99) Minutes
AC Failure Report
Delay (0-999)
Seconds
Cross Zone Time (30-
999)
Sensor Inactivity Time
(0-65535) Minutes
C
...
...
47
P/N 466-5227 • REVA • ISS 26AUG15
Default
Once it is connected to UltraSync the Date and time are
automatically synced.
Once it is connected to UltraSync the Date and time are
automatically synced.
Starting with EST is UTC-5, CST is UTC-6, MT is UTC-6,
UTC 5 ET
PST is UTC-7.
0
This is used in other locations throughout the world.
Mar
Standard
Second
Standard
Nov
Standard
First
Standard
The siren time sets the time in minutes that the siren output
4
is active.
The dynamic battery test time sets the duration in minutes
that the ZeroWire will perform a dynamic battery test. The
ZeroWire will perform a dynamic battery test at the
2
disarming of the first area or at midnight once each 24-
hour cycle. Dynamic battery test is disabled when the test
duration is set to 0. Dynamic battery test can also be run
manually from a keypad.
The AC fail report delay sets the duration in seconds that
the AC power is lost or restored before a communication is
initiated.
300
AC restore will report when power is maintained for this
same duration.
The Cross Zone time sets the duration in seconds whereby
two or more sensors must trip before an alarm condition
will be registered or the one sensor must trigger twice
300
within this time period, or a continuous trip longer than 10
seconds. This feature only applies to sensors with the
Cross Zone feature set in sensor options.
Sensors programmed with Sensor Inactivity in the Sensor
Options must be opened and closed within the time
programmed here (in minutes). If they do not, a Sensor
Inactivity will report. This feature can be enabled in the
0
System Options menu.
Default Sensor Inactivity option is off and this timer is set to
10080 minutes (7 days).
ZeroWire Reference Guide