The ZeroWire Communicator has a powerful automation feature which simulates a user performing
arming and disarming of the system according to a specified schedule.
When a Schedule becomes valid (inside valid time sensor) the ZeroWire will disarm all Areas that are in
the User's - Active Profile - Disarm Area Group. When the Schedule becomes invalid (out of time sensor)
then ZeroWire will arm all areas that are in the User's - Active Profile - Arm Area Group.
For example if we had Schedule 4 Mon-Fri 9am-5pm, and User 55 with permission to arm and disarm
area 1, 2, and 3, plus their schedule was 24 hours 7 days a week.
Then each weekday at 9am the system would disarm areas 1, 2, and 3 as if it were user 55. At 5pm each
weekday the system would arm areas 1, 2, and 3 as if it were user 55.
Arm Disarm Number 1 –Arm-Disarm Example
Schedule 4 – Office Hours
User 55 – Arm-Disarm User
Permission 99 – Full Access
Arm Area Group 1
Disarm Area Group 1
Schedule 1 – Full Access
7 days, 24 hours
For an Arm-Disarm to occur, both the Arm-Disarm schedule here and the User Schedule need to be valid
at the time the Arm-Disarm is triggered.
The Arm-Disarm Schedule determines what the operation is. The leading edge causes a disarming
function and trailing edge causes an arming function. The Users Permissions then determines which
areas if any are armed or disarmed. If the function is to disarm, the Users Disarm Area Groups will be
disarmed. If the function is to arm, the Users Arm Area Group will be armed.
When the time becomes 9am, the Arm-
Disarm tries to disarm all areas using User
55 and their permissions, this includes
checking User 55's schedule.
Arm-Disarm Schedule 9am-5pm
9am
More complex interactions with the system are possible by modifying the schedule selected here, the
schedule assigned to the user, and even combining actions to control schedules. Also, user permissions
can have up to 4 permission and schedule pairs.
C
...
...
116
P/N 466-5227 • REVA • ISS 26AUG15
Mon – Fri
9am – 5pm
1, 2, 3
1, 2, 3
ZeroWire Reference Guide
See Schedule to program
See Users to program
See Permissions to program
See Schedule to program
When the time becomes 5pm, the Arm-Disarm
tries to arm all areas using User 55 and their
permissions, this includes checking User 55's
schedule .