Advertisement

Fire Supervise Time
(120-65535)
Seconds
Burg Supervise
Time (120-65535)
Seconds
Panel Sensor
Doubling
Panel Box Tamper
System Sensor
Tamper
Disable Hardwire
Sensors
Sensor Inactivity
System Channel
C
...
...
48
P/N 466-5227 • REVA • ISS 26AUG15
Option
Default
14400
14400
Off
Off
Off
On
Off
1 Channel
Group
ZeroWire Reference Guide
Function
This applies only to wireless sensors programmed as
fire type. Sensors send a reduced packet count
supervisory signal every 60 minutes (check your sensor
manual for most up to date details). If no supervisory
signal is received by the panel within the time specified
here then the sensor will be reported as missing.
When set to 0 the default of 14,400 seconds (4 hours)
will be used. Check your local regulations for the
correct value to use.
This applies only to wireless sensors programmed as
non-fire type. Sensors send a reduced packet count
supervisory signal every 60 minutes (check your sensor
manual for most up to date details). If no supervisory
signal is received by the panel within the time specified
here then the sensor will be reported as missing.
When set to 0 the default of 43,200 seconds (12 hours)
will be used. Check your local regulations for the
correct value to use.
If enabled, the two (2) hardwired sensor inputs will be
doubled to support four (4) sensors. The terminals for
Sensor 1 will represent sensors 1 and 3, and the
terminals for sensor 2 will represent sensor 2 and 4.
This option cannot be selected for sensors other than
the two sensors on the main panel. This option cannot
be used in conjunction with the DEOL option.
The ZeroWire has a built-in normally closed tamper
switch that will sound the siren if the ZeroWire is
removed from the wall. This option will enable or
disable this tamper switch.
If enabled, the ZeroWire will monitor all sensors, except
fire sensors, for Dual End of Line (DEOL). A short or
open circuit on a DEOL will activate sensor tamper
alarms. This feature cannot be used if Panel Sensor
Doubling is enabled.
If enabled, the ZeroWire will disable all hardwired
sensor inputs.
If enabled, the system ZeroWire will monitor each
sensor for activations. If no activations occur within the
sensor activity time then a failed sensor activity report
may be reported via the selected communication
channel and a failed sensor activity message set in the
ZeroWire event log. For a sensor to be eligible for
activity monitoring, it must have "Sensor Activity" set in
sensor options.
Sensors programmed with Sensor Inactivity in the
Sensor Options must be sealed and unsealed within
the time programmed here (in minutes). If they do not,
a Sensor Inactivity will report.
The Channel Group that the ZeroWire will send system
events to.