To disable the inputs:
Set System Menu -> General Options -> Disable Hardwired Sensors = ON
To enable 2 inputs:
Set System Menu -> General Options -> Disable Hardwire sensors = OFF
Set System Menu -> General Options -> Panel Sensor Doubling = OFF
Set System Menu -> General Options -> Double EOL = ON for tamper monitoring,
or OFF for no tamper
To enable 4 inputs without tamper monitoring:
Set System Menu -> General Options -> Disable Hardwire Sensors = OFF
Set System Menu -> General Options -> Panel Sensor Doubling = ON
Set System Menu -> General Options -> Double EOL = OFF
IMPORTANT NOTES:
If hard wired inputs are programmed as sensor 1, 2, 3, and/or 4, then these will take priority
over the wireless sensors
System Double EOL will take priority over Sensor EOL setting. If Sensor EOL is OFF and
Double EOL is on, Double EOL tamper monitoring will be active.
Normally Open or Normally Closed state can be set in Sensor Options -> Options
Sensor Doubling can only be used with Normally Closed devices
End-Of-Line Resistors for Non-Sensor Double (2 inputs):
End-Of-Line Resistors for Sensor Double (4 inputs):
Resistor Diagram
C
...
...
184
P/N 466-5227 • REVA • ISS 26AUG15
ZeroWire Reference Guide
©2015 United Technologies Corporation
I
..
...
.. .
..