To disable the inputs:
 Set System Menu -> General Options -> Disable Hardwired Sensors = ON
To enable 2 inputs:
 Set System Menu -> General Options -> Disable Hardwire sensors = OFF
 Set System Menu -> General Options -> Panel Sensor Doubling = OFF
 Set System Menu -> General Options -> Double EOL = ON for tamper monitoring,
or OFF for no tamper
To enable 4 inputs without tamper monitoring:
 Set System Menu -> General Options -> Disable Hardwire Sensors = OFF
 Set System Menu -> General Options -> Panel Sensor Doubling = ON
 Set System Menu -> General Options -> Double EOL = OFF
IMPORTANT NOTES:
 If hard wired inputs are programmed as sensor 1, 2, 3, and/or 4, then these will take priority
over the wireless sensors
 System Double EOL will take priority over Sensor EOL setting. If Sensor EOL is OFF and
Double EOL is on, Double EOL tamper monitoring will be active.
 Normally Open or Normally Closed state can be set in Sensor Options -> Options
 Sensor Doubling can only be used with Normally Closed devices
End-Of-Line Resistors for Non-Sensor Double (2 inputs):
End-Of-Line Resistors for Sensor Double (4 inputs):