Sensor Attribute Options (Armed or Disarmed)
• Code Pad Sounder – If enabled, the panel will announce alarm, tamper, or trouble conditions. Default
is on.
• Report Delay – if enabled, the ZeroWire will delay reporting sensor activations until the next scheduled
report. This setting is ignored if the sensor is a Fire type and sensor activations are reported immediately.
When disabled sensor activations (trip, bypass and restorals) are reported immediately. Default is off.
• No Keypad Display – if enabled, any sensor conditions such as alarm and tamper will not illuminate the
Alarm Light. Conditions will still report and function as normal. Default is off.
• Momentary Switch – if enabled, the sensor will not latch. If it is triggered again then it will send another
report immediately. Default is off.
• Sensor Inhibit (Bypass) – This feature is designed to reduce false alarms at arming/disarming. If
enabled, a sensor that is currently faulted that could cause an alarm condition will be temporarily
bypassed when changing armed states.
This typically occurs when forced arming and the sensor is unsealed, or when a schedule change occurs
that changes the sensor type. The bypass will be applied to the sensor if it remains unsealed at the end of
the exit timer. Default is off.
• Swinger Shutdown
Swinger Shutdown is a false alarm prevention feature that counts the number of alarms caused by a
specific sensor.