Interlogix ZeroWire ZW-6400 Reference Manual page 75

Hide thumbs Also See for ZeroWire ZW-6400:
Table of Contents

Advertisement

1General Options
Option
Panel Sensor
Doubling
Panel Box Tamper
System Sensor
Tamper
Enable Celsius
Scale
Disable Hardwire
Sensors
Strobe on Away
System Alarm Latch
Sensor Inactivity
C
...
...
75
P/N 466-5227 • REVA • ISS 26AUG15
Default
If enabled, the two (2) hardwired sensor inputs will be doubled
to support four (4) sensors. The terminals for Sensor 1 will
represent sensors 1 and 3, and the terminals for sensor 2 will
Off
represent sensor 2 and 4. This option cannot be selected for
sensors other than the two sensors on the main panel. This
option cannot be used in conjunction with the DEOL option.
The ZeroWire has a built-in normally closed tamper switch that
Off
will sound the siren if the ZeroWire is removed from the wall.
This option will enable or disable this tamper switch.
If enabled, the ZeroWire will monitor all sensors, except fire
sensors, for Dual End of Line (DEOL). A short or open circuit
Off
on a DEOL will activate sensor tamper alarms. This feature
cannot be used if Panel Sensor Doubling is enabled.
Off
Enable Celsius vs. Fahrenheit Scale.
If enabled, the ZeroWire will disable all hardwired sensor
On
inputs. Wireless sensors with sensor numbers 1 to 16 may still
be used.
If enabled, the system strobe will flash when an area is set in
away mode. The strobe outputs must be configured follow the
Off
area alarm event condition. The strobe is not activated on
Disarm or Stay.
If enabled, system alarms such as tampers, low battery, A/C
fail and trouble requires a user with "Reset System Alarms"
enabled in their current Permission Options to reset the alarm
On
condition.
If disabled, system alarms do not latch and can be reset when
a user arms or disarms an area.
If enabled, the system ZeroWire will monitor each sensor for
activations. If no activations occur within the sensor activity
time then a failed sensor activity report may be reported via the
selected communication channel and a failed sensor activity
message set in the ZeroWire event log. For a sensor to be
eligible for activity monitoring, it must have "Sensor Activity"
Off
set in sensor options.
Sensors programmed with Sensor Inactivity in the Sensor
Options must be sealed and unsealed within the time
programmed here (in minutes). If they do not, a Sensor
Inactivity will report.
ZeroWire Reference Guide
Function
©2015 United Technologies Corporation
I
..
...
.. .
..

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents