Select Area to Configure
Area Name
Entry Time 1 (30-240)
Seconds
Exit Timer 1 (45 - 255)
Seconds
Entry Timer 2 (30 - 240)
Seconds
Exit Timer 2 (45 -255)
Seconds
Stay Enter Timer (30 - 240)
Seconds
Quick Away
Quick Stay Mode Disarm
Manual Panic
Manual Fire
Manual Auxiliary
Force Arm With Bypass
C
...
...
44
P/N 466-5227 • REVA • ISS 26AUG15
Option
ZeroWire Reference Guide
Default
Use the drop down menu to select which of the
Area 1
4 areas to program.
Each area can be configured with a custom 32
character name. The area name is displayed
Blank
wherever an area is referenced on the
ZeroWire system.
Provides time to enter into the premises to
30
deactivate the alarm system.
Provides time to exit the premise without
45
activating the alarm system.
If there is a second entry door that requires
0
more time to deactivate the alarm system.
If there is a second exit door that requires more
0
time to leave.
When the system is armed to "STAY" this will
30
be the entry time to deactivate the alarm
system.
If enabled, the area can be armed in away
mode with a single press. When area is armed
Off
via quick away mode, the closing user number
is the default user of 999.
If enabled, this will allow the stay mode to be
disarmed by pressing the stay key on the
Off
ZeroWire panel. If the system is in alarm a PIN
must be used.
On
Enables or Disables the Keypad Panic
On
Enables or Disables the Keypad Fire
On
Enables or Disables the Keypad Auxiliary
If enabled, the area can be armed even if
sensors are not ready. Any sensors that are not
ready will NOT be automatically be bypassed
and may cause an alarm condition because
they could still be in a not ready state once the
area becomes armed.
Off
This option is overridden if the Force Arm With
Auto-Bypass is enabled.
Individual sensors can be made "force arm-able
without auto-bypass" by leaving this area option
off, then enabling Forced Arm Enable in Sensor
options, and disabling Sensor Inhibit (Bypass)
in the Sensor Type Profile.