4. Enable Ping
Allow the ZeroWire panel to respond to the PING command.
5. Enable Clock Updates
Allow the ZeroWire internal clock to synchronise with the internet time server specified .
6. Enable Web Program
Enabling this option will cause ZeroWire Web Server and UltraSync app to always display Installer menus
regardless of if the panel is in program mode or not.
Disabling this option will hide the Installer menus on ZeroWire Web Server and UltraSync app unless
program mode is active. This provides greater security by keeping web programming disabled unless a
user on site with physical access to the keypad enters program mode with a valid PIN code.
ZeroWire will be in program mode if a user gains access to menu 5, 8, or 9.
UltraSync app requires the Web Access Code to get access to the panel.
7. Always Allow DLX900
Enabling this option will allow DLX900 to connect at any time if the correct Download Access Code is
provided.
Disabling this option provides greater security by only allowing DLX900 to connect when program mode is
active. This allows the system to have DL900 access disabled until a user on site with physical access to
the keypad enters program mode with a valid PIN code.
ZeroWire will be in program mode if a user gains authorised access to menu 5, 8, or 9 on the keypad.
8. Monitor LAN
When the Monitor LAN option is enabled the panel will monitor the Ethernet port for a valid Ethernet cable.
If the Ethernet cable is disconnected while this option is enabled, and the panel is unable to communicate,
it will log a Fail To Communicate event.
9. Enable UltraConnect (UltraSync)
This is an automatic feature of ZeroWire. It is recommended you leave this setting on.
Enable this option to allow ZeroWire to send email reports via the UltraSync servers. This is independent
of the Web Access Passcode which when set to 00000000 will prevent the UltraSync app from
connecting.
If any channel is set to Email format reporting, then ZeroWire will override ignore this setting and allow
email reporting via UltraSync cloud servers.
If you wish to prevent connections to the ZeroWire cloud servers, then uncheck this option and do not use
the UltraSync reporting format.
Features
Enable UltraSync = OFF
Web Access Code = 00000000
Enable UltraSync = OFF
Web Access Code = not 00000000
Enable UltraSync = ON
Web Access Code = 00000000
Enable UltraSync = ON
Web Access Code = not 00000000
C
...
...
104
P/N 466-5227 • REVA • ISS 26AUG15
Email Reports
No
Yes
Yes
Yes
ZeroWire Reference Guide
UltraSync App
No
Yes
No
Yes
©2015 United Technologies Corporation