upgrade system
Upgrade the Dell Networking OS image to the stack-unit.
C9000 Series
Syntax
upgrade system {stack-unit unit number | all } {usbflash: | flash:}
{rpmA:|rpmB:}
Parameters
stack-unit unit
number
all
flash: file-url
usbflash: file-url
rpmA: | rpm B:
Defaults
none
Command Modes
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant
Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
9.9(0.0)
9.7(0.0)
Enter the keyword stack-unit and specify the stack-unit ID to sync the
image to that of the stack-unit or enter all to sync the image on all
stack-units. The stack-unit number range is from 0 to 7.
Enter the keyword all to sync the image on all the stack-units
configured.
Enter the keyword flash: and specify the location of the image file in the
format //directory-path or press Enter to launch a prompt sequence.
Enter the keyword usbflash: and copy the image from usbflash file
systemusbflash://filepath press Enter to launch a prompt sequence.
Specify the flash partition of the operating-system image that you want to
upgrade.
Description
Introduced on the C9010 and C1048P.
Added support for NFS mount.
PE Console Commands