4. Replacement and Adjustment
5. Cover the top of the tank with some paper and tape, and then discard it.
• Follow the local laws and regulations regarding the disposal of this item.
• Never attempt to empty the right ink sump and re-use it.
6. After installing the new right ink sump, open SP2505-002 (Clear Counter) and touch [EXECUTE] to
clear the counter for the new sump.

Maintenance Unit

You can check the status of the maintenance unit with two counters:
• SP2231-003 (PM Counter Indication - Maintenance Unit). Displays the status of the maintenance
unit as the amount of usage remaining (a percent).
• SP2231-008 (PM Counter Indication - PM Counter Maintenance Unit). Displays the status of the
maintenance unit as the distance (mm) of paper fed
Preparation
• Move the Carriage Unit with SP2102-4
• Separate the Main Unit from the Scanner Unit
Remove:
• Ink collector tank
• Right cover
• Right upper cover
• Ink cartridge cover
1. Set several sheets of clean paper on a flat surface to hold the maintenance unit after it is removed.