• DRESS sensor harness loose, broken, defective
• DRESS sensor defective
D
OCFS Ink Pump Reverse Suction Error
The OCFS could not detect when the supply pump motor reversed because a
feeler was broken or out of position, or an ink supply pump could not siphon
ink.
D
Head 1
D
Head 2
D
Head 3
D
Head 4
D
Head 5
• Cycle the machine off/on
• Replace print head (with new OCFS)
• Replace ink supply unit
D
OCFS Ink Timeout During Filling
The OCFS feeler is out of position and cannot be read, or one of the ink
supply pumps is not pumping ink
D
Head 1
D
Head 2
D
Head 3
D
Head 4
D
Head 5
• Replace the ink supply unit
• Replace ink end sensor