7. Push each ferrite core [C] back through the slot so they are no longer visible.
8. Reconnect the FFCs and clamp the harness (
After Installation of a New CIS
1. Turn the machine on.
2. Go into the SP mode and do the following SP codes. (The SP code settings are listed on the sheet
provided with the new CIS unit.)
• SP4709-001 to 015
• SP4972-001 to 010
• SP4979-001 to 060
3. Cycle the machine off/on.
4. Go into the SP mode and open SP4417.
5. Select Pattern 8 and touch [OK].
6. At the top of the screen, touch [Copy Window].
7. Set one blank sheet of A3 LEF paper on the original table.
8. Touch the Copy key and wait for the machine to print the pattern.
9. At the top of the Copy Window, touch [SP Mode] to return to the SP mode.
10. Check the printed pattern.
x5,
x3).
Scanner