There are frequent ink pump motor timeouts during ink filling. (There are 5 timeouts for
each ink tank during initial ink filling.) Every time an ink pump switches on, the firmware
checks to confirm that the OCFS is on. If the OCFS does not come on after 2 sec., the
motor switches off.
[0 to 9999/6/1 hour]
2 Reversal Rotation Period
The minimum pumping rate for ink supply is 0.25 ml/sec. However, the Duty of each ink
cartridge pump motor is temperature dependent.
• The higher the temperature, the slower the pump motor operates to pump ink
• Lowering the Duty of the ink pump motor with a rise in temperature controls the
• The machine uses the readings of the temperature/humidity sensor to set the Duty
• These Duty settings apply to both forward and reverse operation of the pump
Use this SP to adjust the setting manually.
[0 to 10/0.35/0.01 sec.]
3 Pause Before Normal Rotation
[0 to 10/0.1/0.01 sec]
4 Pump Stop Time P1
Displays count for P1 pump (K1).
[0 to 0xFFFF FFFF/0/1]
5 Pump Stop Time P2
Displays count for P2 pump (K2).
[0 to 0xFFFF FFFF/0/1]
6 Pump Stop Time P3
Displays count for P3 pump (C).
[0 to 0xFFFF FFFF/0/1]
7 Pump Stop Time P4
70
(forward and reverse).
amount ink pumped.
for operation of the ink cartridge pump motors.
motors.