2. Appendix 2: Service Program Mode
[0 to 600/0/1 count]
7 HT2 (Filling Trigger Position)
[0 to 600/0/1 count]
8 HT3 (Filling Trigger Position)
[0 to 600/0/1 count]
9 HT4 (Filling Trigger Position)
[0 to 600/0/1 count]
10 HT5 (Filling Trigger Position)
[0 to 600/0/1 count]
2210
Air Leakage Alert Monitor Mode
This SP switches air leakage alert mode on/off. When the machine is in the air leakage
alert mode:
• When a print job ends, the difference between the count for the occurrences of air
• If the result exceeds the threshold, the machine issues SC282-11 to 15, and then
• If normal operation cannot be restored by cycling the machine off/on, the machine
This SP prevents ink spillage if leaks exist during ink supply pumping, air tank purging,
ink filling, and print head maintenance.
[0 to 1/0/1] 0: Off 1: On
2211
Air Detection Freq. Check Result
Use this SP to display the current status of the air leak alert monitor turned on with
SP2210.
• If the difference between the number of leakage detections for the previous and
• If the difference does not exceed threshold, the machine returns "Normal".
1 Carriage Unit (Black)
56
detections the previous day and the current count is compared to the threshold
value.
shuts down.
cannot be used until the problem has been solved.
present period exceeds threshold, the machine returns "Abnormal".