Displays the cause of an RCG error. Where Cumin is used, normally displays "0".
[0 to 1/0/1] 0:Normal condition 1:Error
• If "1" is displayed, this means that the authentication from client to server failed when
the network re-booted.
• To restore normal operation, cycle the machine off/on to return a "0" (normal
condition).
RCG – C Registed
This SP displays the Embedded RC Gate installation end flag.
21
0: Installation not completed
1: Installation completed
Connect Type (N/M)
This SP displays and selects the Embedded RC Gate connection method.
23
[0 or 1/0/1 /step
0: Internet connection
1: Dial-up connection
Cert. Expire Timing DFU
61
Proximity of the expiration of the certification.
Use Proxy
62
This SP setting determines if the proxy server is used when the machine communicates with
the service center.
Proxy Host
This SP sets the address of the proxy server used for communication between Embedded
RC Gate-N and the gateway. Use this SP to set up or display the customer proxy server
63
address. The address is necessary to set up Embedded RC Gate-N.
Note: The address display is limited to 128 characters. Characters beyond the 128
character are ignored. This address is customer information and is not printed in the SMC
report.
SP5000
175