Conversion Instructions
Applicable Program Areas
Operands
Operand Specifications
Block program areas
OK
S: Source Word
The data in the source word indicates the location of the bit(s) that will be
turned ON.
C: Control Word
The control word specifies whether MLPX(076) will perform a 4-to-16 bit con-
version or an 8-to-256 bit conversion, the number of digits or bytes to be con-
verted, and the starting digit or byte.
Digit number: 3 2 1 0
0
R: First result word
There can be anywhere from 1 to 32 result words, depending upon the type of
conversion process and number of digits/bytes being converted. The result
words must be in the same data area.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Step program areas
OK
OK
Specifies the first digit/byte to be converted
4-to-16: 0 to 3 (digit 0 to 3)
8-to-256: 0 or 1 (byte 0 or 1)
Number of digits/bytes to be converted
4-to-16: 0 to 3 (1 to 4 digits)
8-to-256: 0 or 1 (1 or 2 bytes)
Conversion process
0: 4-to-16 bits (digit to word)
1: 8-to-256 bits (byte to 16-word range)
S
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A000 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
---
Specified values
only
DR0 to DR15
Section 3-12
Subroutines
Interrupt tasks
OK
C
R
A448 to A959
---
---
441