Omron CS1G/H-CPUxxH Instructions Manual page 913

Sysmac cs series; sysmac cj series
Hide thumbs Also See for CS1G/H-CPUxxH:
Table of Contents

Advertisement

Network Instructions
Description
892
Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
CMND(490) transfers the specified number of bytes of FINS command data
beginning at word S to the designated device through the PLC's CPU Bus or
over a network. The response is stored in memory beginning at word D.
Local node
CMND(490) can be used to transmit command data to a particular serial port
in the destination device as well as the device itself. CMND(490) operates just
like SEND(090) if the FINS command code is 0102 (MEMORY AREA WRITE)
and just like RECV(098) if the code is 0101 (MEMORY AREA READ).
The CPU Unit executing CMND(490) can send a FINS command to itself
(except for CS-series CS1 CPU Units prior to V1@). Use the following control
data settings to achieve this.
• Destination network address (bits 00 to 07 of C+2): 00 Hex (local network)
• Serial port No. (bits 08 to 11 of C+2): 0 Hex (not used)
• Destination unit address (bits 00 to 07 of C+3): 00 Hex (CPU Unit)
• Destination node address (bits 08 to 15 of C+3): 00 Hex (local node)
• Number of retries (bits 00 to 03 of C+4): 0 Hex (this setting is invalid; set it
to 0)
S
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
---
---
---
,IR0 to ,IR15
–2048 to +2047, IR0 to –2048 to +2047, IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Command
Command
data (n by-
tes)
Response
Response
data (m
bytes)
Section 3-25
C
D
E00000 to
E32762
En_00000 to
En_32763
(n = 0 to C)
Destination node
Interpret
Execute