Sequence Control Instructions
3-5-4
JUMP and JUMP END: JMP(004) and JME(005)
Purpose
Ladder Symbols
Variations
Applicable Program Areas
When the execution condition for JMP(004) is OFF, program execution jumps
directly to the first JME(005) in the program with the same jump number.
JMP(004) and JME(005) are used in pairs.
Variations
Jumps when OFF/Doesn't jump when ON
Immediate Refreshing Specification
Variations
Executed Each Cycle for ON Condition
Immediate Refreshing Specification
Block program areas
OK
Not allowed
CIO 000000
CIO 000000
ON
OFF
OFF
Normal
execution
Reset
Retained
Retained
JMP(004)
N
N: Jump number
JME(005)
N
N: Jump number
Step program areas
Subroutines
OK
Section 3-5
OFF
Outputs
interlocked
JMP(004)
Not supported
JME(005)
Not supported
Interrupt tasks
OK