Omron CS1G/H-CPUxxH Instructions Manual page 205

Sysmac cs series; sysmac cj series
Hide thumbs Also See for CS1G/H-CPUxxH:
Table of Contents

Advertisement

Sequence Output Instructions
3-4-8
SINGLE BIT OUTPUT: OUTB(534)
Purpose
Ladder Symbols
Variations
Applicable Program Areas
Operands
Operand Specifications
184
OUTB(534) outputs the status of the instruction's execution condition to the
specified bit. OUTB(534) can control a bit in the DM Area or EM Area, unlike
OUT.
This instruction is supported by the CS1-H, CJ1-H, CJ1M, and CS1D CPU
Units only.
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification (See note.)
Note Immediate refreshing is not supported by the CS1D CPU Units.
Block program areas
Not allowed
D: Word Address
Specifies the word containing the bit to be controlled.
N: Beginning Bit
Specifies the bit to be controlled. N must be #0000 to #000F (&0 to &15).
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM addresses in
binary
Indirect DM/EM addresses in
BCD
Constants
Data Registers
OUTB(534)
D: Word address
D
N: Bit number
N
Step program areas
Subroutines
OK
OK
D
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A448 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
---
DR0 to DR15
Section 3-4
OUTB(534)
@OUTB(534)
!OUTB(534)
Interrupt tasks
OK
N
A000 to A959
#0000 to #000F (binary)
or &0 to &15