◆ Alarm and Error Displays

Faults
Table 6.2
gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is
important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the digital operator, and the fault
contact MA-MB-MC triggers. An alarm is present if the ALM LED blinks and the fault code on the digital operator
flashes. Refer to
Minor Faults and Alarms on page 254
boL
Braking Transistor Overload
bUS
Option Communication Error
MEMOBUS/Modbus Communication
CE
Error
CF
Control Fault
,
CPF00, CPF01
Control Circuit Error
<1>
CPF02
A/D Conversion Error
CPF03
Control Board Connection Error
CPF06
EEPROM Data Error
,
CPF07,
Terminal Board Connection Error
CPF08
,
CPF20, CPF21
Control Circuit Error
<1>
CPF22
Hybrid IC Failure
CPF23
Control Board Connection Error
CPF24
Drive Unit Signal Fault
to
CPF26 to CPF34 Control Circuit Error
Speed Deviation (for Control Mode with
dEv
Encoder)
dv1
Encoder Z Pulse Fault
dv2
Z Pulse Noise Fault Detection
dv3
Inversion Detection
dv4
Inversion Prevention Detection
dv6
Overacceleration Detection
dv7
Rotor Polarity Detection Timeover
dv8
PM Rotor Position Estimation Error
EF0
Option Card External Fault
to
EF3 to EF8
External Fault (input terminal S3 to S8)
Err
EEPROM Write Error
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
for a list of alarm codes.
Table 6.2 Fault Displays (1)
257
257
257
257
257
257
258
,
258
,
258
to
258
258
to
258
258
258
,
259
259
to
259
259
259
259
260
,
260
260
to
260
260
6.2 Drive Alarms, Faults, and Errors
FrL
Speed Reference Missing
GF
Ground Fault
LF
Output Phase Loss
LF2
Output Current Imbalance
oC
Overcurrent
Option Card Connection Error at Option
oFA00
Connector CN5-A
Option Card Fault at Option Connector
oFA01
CN5-A
oFA05, oFA06
oFA10, oFA11
Option Card Error Occurred at Option Port
CN5-A
oFA12 to oFA17
oFA30 to oFA43
oFb00
Option Card Connection Error (CN5-B)
oFb01
Option Card Fault (CN5-B)
oFb02
Option Card Fault (CN5-B)
oFb03, oFb11
Option Card Error (CN5-B)
oFb12 to oFb17
Option Card Connection Error (CN5-B)
oFC00
Option Card Connection Error (CN5-C)
oFC01
Option Card Fault (CN5-C)
oFC02
Option Card Fault (CN5-C)
oFC03, oFC11
Option Card Error (CN5-C)
oFC12 to oFC17
Option Card Connection Error (CN5-C)
oFC50