5.3 Drive Alarms, Faults, and Errors
u

Alarm and Error Displays

n
Faults
Table 5.5
gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is important
to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the HOA keypad, and the fault contact
MA-MB-MC triggers. An alarm is present if the ALM LED blinks and the fault code on the HOA keypad flashes.
Minor Faults and Alarms on page 205
HOA
Keypad
Display
bAT
HOA Keypad Battery Voltage Low
bUS
Option Communication Error
CE
MEMOBUS/Modbus Communication Error
CoF
Current Offset Fault
CPF00,
CPF01
Control Circuit Error
<1>
CPF02
A/D Conversion Error
CPF03
Control Board Connection Error
CPF06
EEPROM Memory Data Error
CPF07,
Terminal Board Connection Error
CPF08
CPF20,
CPF21
Control Circuit Error
<2>
CPF22
Hybrid IC Error
CPF23
Control Board Connection Error
CPF24
Drive Unit Signal Fault
CPF46
Terminal Board Error
EF0
Option Card External Fault
EF1 to EF7 External Fault (input terminal S1 to S7)
Err
EEPROM Write Error
FAn
Internal Fan Fault
Fn1
External Fan Fault
FbH
Excessive PI Feedback
FbL
PI Feedback Loss
GF
Ground Fault
LF
Output Phase Loss
LF2
Current Imbalance
nSE
Node Setup Error
oC
Overcurrent
oFA00
Option Card Connection Error (CN5)
<1> Displayed as CPF00 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
CPF01.
<2> Displayed as CPF20 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
CPF21.
204
for a list of alarm codes.
Table 5.5 Fault Displays
Name
HOA
Page
Keypad
Display
207
oFA01
Option Card Fault (CN5)
207
oFA05,
Option Card Error (CN5)
oFA06
207
oFA10,
207
Option Card Error (CN5)
oFA11
oFA12 to
Option Card Connection Error (CN5)
208
oFA17
oFA30 to
Comm Option Card Connection Error (CN5)
208
oFA43
208
oH
Heatsink Overheat
208
oH1
Heatsink Overheat
oH3
Motor Overheat Alarm (PTC input)
208
oH4
Motor Overheat Fault (PTC input)
oL1
Motor Overload
208
oL2
Drive Overload
209
oL3
Overtorque Detection 1
209
oL7
High Slip Braking oL
209
oPr
Operator Connection Fault
209
ov
Overvoltage
209
ov2
Overvoltage 2
209
PF
Input Phase Loss
210
SEr
Too Many Speed Search Restarts
209
STo
Pull-Out Detection
210
TdE
Time Data Error
210
TIM
Time Not Set
211
UL3
Undertorque Detection 1
211
UL6
Motor Underload
211
Uv1
DC Bus Undervoltage
211
Uv2
Control Power Supply Undervoltage
211
Uv3
Soft Charge Circuit Fault
212
voF
Output Voltage Detection Fault
213
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Refer to
Name
Page
213
213
213
213
213
213
213
213
214
214
215
215
215
215
216
216
216
217
217
217
217
218
218
218
218
219
219

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents