5-16 User Parameters
Pn26
Setting range
• Use this parameter to set the Servomotor's allowable operating range for the position command
input range.
• An overrun limit error (alarm code 34) will occur if the setting is exceeded.
• The function will be disabled if the setting is 0.
• For details, refer to Overrun Limit on page 5-19.
Pn27
Instantaneous Speed Observer Setting
Setting range
Explanation of Settings
5
• The instantaneous speed observer can both increase the responsiveness and reduce vibration at
stopping by improving the speed detection accuracy for devices with high rigidity.
• The Inertia Ratio (Pn20) must be set correctly.
• The Instantaneous Speed Observer Setting (Pn27) will be 0 (disabled) if the Realtime Autotuning
Mode Selection (Pn21) is not set to 0 (enabled).
Pn28
Notch Filter 2 Frequency
Setting range
• Use this parameter to set the notch frequency of notch filter 2 for resonance suppression.
• The notch filter will be disabled if the setting is 1500.
Pn29
Notch Filter 2 Width
Setting range
• Use this parameter to set the notch width of notch filter 2 for resonance suppression.
• Increasing the setting will increase the notch width. Normally, use the default setting.
Pn2A
Notch Filter 2 Depth
Setting range
• Use this parameter to set the notch depth of notch filter 2 for resonance suppression.
• Increasing the setting will decrease the notch depth and the phase lag.
Pn2B
Vibration Frequency 1
Setting range
• Use this parameter to set vibration frequency 1 for damping control to suppress vibration at the
end of the load.
• Measure the frequency at the end of the load and make the setting in units of 0.1 Hz.
• Setting frequency: 10.0 to 200.0 Hz. The function will be disabled if the setting is 0 to 9.9 Hz.
• Refer to Damping Control on page 7-35 for more information.
5-65
Overrun Limit Setting
0 to 1000
Unit
0 to 1
Unit
Setting
0
Disabled
1
Enabled
100 to 1500
Unit
0 to 4
Unit
0 to 99
Unit
0 to 2000
Unit
0.1 revolution
Default setting
---
Default setting
Explanation
Hz
Default setting
---
Default setting
---
Default setting
0.1 Hz
Default setting
Position
10
---
Power OFF→ON
Position Speed
0
---
Power OFF→ON
All modes
1500
---
Power OFF→ON
All modes
2
---
Power OFF→ON
All modes
0
---
Power OFF→ON
Position
0
---
Power OFF→ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-g series

Table of Contents