• No-fuse breakers, surge absorbers, and noise filters should be positioned near the input terminal
block (ground plate), and I/O lines should be separated and wired at the shortest distance.
R88D-GT75H
Three-phase:
200 VAC
SG
Single-phase:
100 VAC
Unit Details
Symbol
SG
Surge absorber
NF
Noise filter
SV
Servo Drive
SM
Servomotor
FC
Clamp core
TB
Controller
*1. A specified combination of Servo Drive and Servomotor must be used.
4-3 Wiring Conforming to EMC Directives
FC
L1
NF
L2
L3
L1C
L2C
FC
TB Controller
Name
Manufacturer
Okaya Electric
Industries Co., Ltd.
Okaya Electric
Industries Co., Ltd.
OMRON Corp.
OMRON Corp.
TDK
---
SV
FC
U
CNA
CNB
V
W
FC
CN1
CN2
Model
RAV781BWZ-4
RAV781BXZ-4
SPU-EK5-ER-6
3SUP-HQ10-ER-6
3SUP-HU30-ER-6
3SUP-HL50-ER-6B
---
---
ZCAT3035-1330
---
SM
Remarks
Single-phase 100 VAC
Three-phase 200 VAC
Single-phase
100/200 VAC (5 A)
Three-phase 200 VAC
(10 A)
Three-phase 200 VAC
(30 A)
Three-phase 200 VAC
(50 A)
*1
*1
---
Switch box
4-28