Installing the Decelerator
When installing the R88G-HPG@@@, first make sure that the mounting surface is flat and that there
are no burrs on the tap sections, and then bolt on the mounting flanges.
Mounting Flange Bolt Tightening Torque for Aluminum
R88G-HPG
Number of bolts
Bolt size
Mounting PCD (mm)
Tightening torque (N·m)
B
E
11
14
4
4
M3
M5
46
70
1.4
6.3
4-1 Installation Conditions
C
F
20
32
50
4
4
4
M8
M10
M12
105
135
190
26.1
51.5
103
D
4
65
4
M16
260
255
4-8