Omron R88D-GT series User Manual page 254

Omnuc g series ac servomotors/servo drives
Table of Contents

Advertisement

4-2 Wiring
 R88D-GT20H/-GT30H/-GT50H
(Ground to
4
100 Ω or less.)
1MC
2MC
Reactor
Regeneration
resistor
24 VDC
User
control
device
Control Cable
4-19
R
S
T
Three-phase 200 to 230 VAC 50/60 Hz
NFB
Noise filter
1
2
3
(*1)
NF
E
4
5
6
Main circuit power supply
OFF
ON
1MC
X
OMNUC G-Series
AC Servo Drive
TB1
L1C
L2C
TB1
L1
L2
L3
B1
(*4)
B3
B2
CN1
X
37
/ALM
36
ALMCOM
X
CN1
BKIRCOM
Main-circuit contactor (*1)
X
1MC
Surge suppressor (*1)
PL
Servo error display
Power Cable
XB
TB1
U
24 VDC
V
W
(Ground to
100 Ω or less.)
CN2
Encoder Cable
*1.
*2.
CN1
24 VDC
XB
BKIR
11
(*2)
*3.
10
*4.
OMNUC G-Series
AC Servomotor
(*3)
B
M
E
Recommended products are listed in 4-3
Wiring Conforming to EMC Directives.
Also, to ensure safety (i.e., to ensure that
the power supply can be shut OFF) for
contactor welding, we recommend using
two magnetic contactors (MC).
Recommended relay: MY Relay (24 V),
by OMRON. For example, the MY2
Relay's rated inductive load is 2 A at 24
VDC and applicable to all G-Series
Servomotors with brakes.
The brake is not affected by the polarity
of the power supply.
Connect B2-B3 for the models with a
built-in regeneration resistor (GT20H to
GT50H). If the amount of regeneration
is large, disconnect B2-B3 and connect
an External Regeneration Resistor to
B1-B2.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-g series

Table of Contents